| Load-cell gravimetric filling | Load cells weigh the tank or vessel as product enters. A controller slows or stops the pump or valve when the target mass is reached. | Weight; suitable systems can commonly control batch mass to within roughly 0.1–0.5% under appropriate conditions. | Batching where mass is the required measure, including liquids whose density changes with temperature or formulation. | Measures product mass directly and does not rely on a fixed density-to-volume conversion. | Tank supports, pipe connections, vibration, and mechanical forces can affect readings. Check scale capacity, calibration, and installation design. |
| Coriolis mass-flow batching | A Coriolis meter measures mass flow in the filling line. The controller totals the measured flow and closes the valve or stops the pump at the batch target. | Mass flow; meter accuracy is often specified around ±0.1–0.2% of reading for suitable liquid applications, subject to model and conditions. | Higher-value batches, recipe dosing, and processes that need mass-flow measurement or additional fluid data. | Can measure mass without a separate density input and can provide repeatable batch totals. | Evaluate purchase cost, line size, pressure drop, flow range, entrained gas, and compatibility with the liquid and cleaning process. |
| Magnetic flowmeter filling | A magnetic flowmeter measures the volume of conductive liquid moving through a full pipe. A batch controller stops flow when the preset volume is reached. | Volumetric flow; accuracy commonly falls around ±0.2–0.5% of reading for appropriately selected and installed meters. | Conductive liquids in full-pipe systems, such as many water-based products and process fluids. | No moving parts in the flow path; useful for continuous measurement and batch control. | Not suitable for non-conductive liquids such as many oils. Confirm minimum conductivity, grounding, pipe-full conditions, and liner compatibility. |
| Positive-displacement meter filling | The meter counts fixed volumes as liquid passes through it. A preset counter or controller stops the filling cycle at the selected total. | Volumetric total; performance depends on meter design, fluid properties, operating range, and calibration. | Many clean, compatible liquids, including some viscous products and applications with steady, measurable flow. | Measures volume directly and can work with liquids that are unsuitable for magnetic meters. | Check viscosity range, solids, wear, pressure drop, seal materials, and maintenance needs. Meter performance can vary with flow and fluid conditions. |
| Level-sensor-controlled filling | A level instrument measures liquid height or level in the tank. A PLC starts, modulates, or stops the inlet valve or pump at configured setpoints. | Tank level; volume accuracy depends on tank geometry, sensor technology, installation, and calibration. | Maintaining tank inventory, high/low-level control, and preventing overflow or dry running. | Supports continuous tank management and can provide independent high-level alarms. | Level is not always a precise batch measure. Consider foam, vapor, agitation, tank shape, sensor access, and independent overfill protection. |
| Timed pump or valve filling | A controller runs a pump or opens a valve for a preset duration. The target quantity is estimated from a previously established flow rate. | Elapsed time and estimated flow; no direct measurement of each batch quantity. | Simple, low-cost transfer tasks where quantity tolerance is broad and operating conditions remain stable. | Simple controls and relatively low instrumentation requirements. | Flow changes with pressure, temperature, viscosity, and equipment wear, so this method is generally less repeatable than measured batching. |