| L-coded | 4 contacts; some versions add a functional-earth contact | DC power | Commonly up to 63 V DC and 16 A per contact, depending on the connector design | Power distribution to industrial I/O modules, field devices, and compact equipment | Confirm pin arrangement, current derating, cable size, mating compatibility, and whether functional earth is required. |
| T-coded | 4 contacts | DC power | Commonly up to 63 V DC and 12 A per contact, depending on the connector design | DC power connections for sensors, actuators, and automation devices | Check the required current, voltage drop, conductor cross-section, and compatibility with the device’s coding. |
| S-coded | Commonly 3 or 4 contacts, including protective earth where specified | AC power | Commonly up to 630 V AC and 12 A per contact, depending on the connector design | AC power connections for motors and industrial equipment | Verify the exact pole configuration, protective-earth connection, voltage rating, and suitability for the installation environment. |
| K-coded | Commonly 4 or 5 contacts, including protective earth where specified | AC power | Commonly up to 630 V AC and 12 A per contact, depending on the connector design | AC power connections where a dedicated power-coded interface is needed | Confirm the contact layout and earth arrangement against the equipment interface; do not assume it mates with S-coded connectors. |
| A-coded | Commonly 2, 3, 4, or 5 contacts | Usually signal or low-power DC; not a dedicated M12 power coding | Ratings vary by contact count and product; many versions are rated around 4 A per contact, but the product datasheet governs | Sensors, control signals, and low-power devices | Use for power only when the device documentation explicitly permits it and the current, voltage, and pin assignments are suitable. |