| 1 | C-stud | C-shaped section; commonly supplied in nominal web widths such as 50, 70, 92, or 100 mm. Thickness and dimensions vary by system. | Vertical framing member in non-load-bearing partition walls; supports plasterboard fixed to its flanges. | Web and flange dimensions, steel thickness, coating, available lengths, and compatibility with the matching track. |
| 2 | U-track | U-shaped channel sized to suit the associated stud system. | Installed horizontally at the floor and ceiling to locate and retain the ends of wall studs. | Matching stud size, section tolerances, thickness, cut-length options, and whether the system requires a deflection detail. |
| 3 | Furring channel | Shallow channel profile; depth and flange geometry depend on the ceiling or wall system. | Creates a fixing plane for plasterboard on ceilings or existing walls and can help accommodate services or uneven substrates. | Channel dimensions, compatible clips or brackets, maximum spans specified by the system, and corrosion-protection requirements. |
| 4 | Hat channel | Hat-shaped section with a raised center and two fixing flanges; sizes vary by application. | Provides a secondary framing layer for walls and ceilings, including installations where a stand-off from the substrate is needed. | Profile depth, flange width, steel thickness, attachment method, and published load or span data for the intended assembly. |
| 5 | Resilient channel | Thin, formed channel designed to provide a flexible mounting connection; profile geometry is system-specific. | Used between framing and gypsum board in certain wall or ceiling assemblies to reduce direct mechanical sound transmission. | Tested assembly details, installation orientation, fastener locations, and compatibility with the specified board and framing. |
| 6 | Carrying channel | Primary ceiling channel, often used with separate furring or secondary channels. | Forms part of a suspended ceiling grid, transferring ceiling loads through hangers to the supporting structure. | System layout, hanger spacing, connection components, allowable loads, and applicable installation instructions. |
| 7 | Deflection track | Deep-leg or slotted track designed to allow controlled vertical movement; details vary by system. | Used at the head of a partition where floor or roof movement must be accommodated without transferring unwanted movement to the wall. | Movement capacity, stud engagement requirements, fire- and acoustic-rated assembly details, and compatible fasteners. |
| 8 | Shaftwall stud or C-H stud | Specially formed steel stud designed to work with shaftwall liner panels and related components. | Frames elevator, stair, and service shafts, often from one side where access to the inside face is restricted. | Complete system components, tested fire-resistance assemblies, maximum wall heights, and project-specific approvals. |
| 9 | Corner bead | Perforated or expanded-metal angle profile; leg width and finish depend on the product. | Reinforces and creates a straight external corner on plasterboard walls before joint compound or finishing coats are applied. | Material, corrosion resistance, leg dimensions, fixing method, and suitability for the specified interior or exterior exposure. |
| 10 | Edge or shadow-gap profile | Metal edge section with a visible reveal or defined board termination; shape and reveal width vary. | Finishes exposed board edges and creates a deliberate recessed joint or clean transition at ceilings and openings. | Reveal dimensions, board-thickness compatibility, finish options, installation details, and availability of matching accessories. |