| Clean liquid flow control | 0–150 °C; up to 25 bar; low viscosity; no solids | Globe valve with equal-percentage trim; reduced or full port as required | Select Cv or Kv from minimum, normal, and maximum flow; verify cavitation margin | Stable throttling over a wide load range | Fail closed for hazardous or overheating services; fail open for cooling or minimum-flow protection |
| High-pressure liquid letdown | Pressure drop above approximately 10 bar; liquid near vapor pressure | Globe valve with anti-cavitation multistage or low-noise trim | Check for flashing, cavitation, outlet velocity, trim wear, and body pressure rating | Pressure reduction without damaging vapor-bubble collapse | Usually fail closed when uncontrolled downstream flow is unsafe |
| Gas or compressed-air flow | Gas service; pressure ratio may approach the critical-flow region; low to moderate temperature | Globe valve with streamlined, low-noise trim; rotary valve may be suitable for large diameters | Use absolute pressure and temperature; include molecular weight, compressibility, and specific-heat ratio in sizing | Accurate gas flow control with acceptable noise and vibration | Fail closed for fuel or toxic gas isolation; fail open where continuous purge is essential |
| Steam pressure or temperature control | Saturated or superheated steam; commonly 2–40 bar(g); temperature depends on pressure and superheat | Globe valve with hardened, anti-noise trim; desuperheating may be required downstream | Evaluate choked flow, noise, erosion, thermal expansion, and downstream pipe velocity | Maintain header pressure or process temperature without excessive noise | Fail closed when excess steam can damage equipment; fail open for freeze protection when specified |
| Corrosive chemical service | pH, concentration, temperature, and chloride content vary significantly | Globe, lined rotary, or diaphragm valve depending on compatibility and leakage requirements | Confirm wetted-material compatibility, gasket selection, corrosion allowance, and fugitive-emission requirements | Reliable modulation with minimum external leakage | Select according to the consequence of chemical release and the safe state of the process |
| Slurry or liquid containing solids | Solids may exceed 1% by volume; particle size and hardness determine wear rate | Eccentric rotary, ball, pinch, or diaphragm valve with abrasion-resistant wetted parts | Consider settling, plugging, erosion, minimum velocity, flush connections, and full-port requirements | On/off isolation or moderate throttling with high wear resistance | Determine whether fail open or fail closed prevents line blockage or protects downstream equipment |
| High-viscosity liquid | Viscosity may exceed 100 mPa·s; flow can be temperature-dependent | Rotary ball or eccentric plug valve; jacketed body may be needed for temperature-sensitive fluids | Correct liquid viscosity in the valve-sizing calculation; check actuator torque and reduced flow capacity | Prevent plugging while maintaining repeatable flow | Usually fail open where solidification or line blockage is the main risk |
| Vacuum or low-pressure service | Absolute pressure below atmospheric; possible gas leakage or air ingress | Low-leakage globe or rotary valve with vacuum-rated packing and seals | Check inward leakage, seat leakage class, packing arrangement, and actuator sizing at low differential pressure | Maintain vacuum stability and prevent contamination | Select the position that preserves vacuum integrity and protects the process during instrument-air failure |
| Fast pressure or flow response | Rapid load changes; short residence time; possible process oscillation | Small, low-friction rotary valve or properly sized globe valve with digital position feedback | Avoid oversizing; verify actuator stroke time, valve gain, dead band, installed characteristic, and loop tuning | Fast response without hunting or excessive overshoot | Based on the safe process state, emergency shutdown philosophy, and loss-of-utility analysis |