| Primary voltage | Nominal input voltage, permitted operating range, and system type. | Examples include 120 V or 230 V single-phase supplies, or 400/480 V three-phase systems. | Match the transformer primary rating to the actual supply and its expected voltage variation. Do not assume that a device supports every voltage in a nominal category. |
| Secondary voltage | Required output voltage and allowable tolerance for the connected gateway and other loads. | Common control-power examples include 24 V AC or 24 V DC, depending on the equipment design. | Check the gateway input label and account for voltage drop in wiring and any load-dependent regulation. |
| Frequency | Compatibility with the local AC supply frequency. | Many AC systems operate at 50 Hz or 60 Hz; some equipment is rated for both. | Verify the rated frequency on the transformer and connected equipment. Frequency compatibility should not be inferred from voltage compatibility. |
| Power capacity | Transformer apparent-power rating and the total connected load, including startup or inrush demand. | Capacity is commonly specified in volt-amperes (VA). The required rating depends on the gateway and any auxiliary devices powered from the same secondary. | Sum the load requirements and follow manufacturer derating guidance. Allow suitable margin without exceeding the secondary circuit or protection ratings. |
| Isolation and grounding | Whether galvanic isolation is needed between primary and secondary, and how the secondary is referenced to ground. | Isolation voltage and grounding arrangements are product- and installation-specific. | Confirm insulation ratings, protective-earth requirements, and whether the secondary must be floating or grounded. Follow local electrical codes and the device instructions. |
| Protection | Overcurrent, short-circuit, thermal, surge, and fault protection requirements. | Protection may include correctly rated fuses or circuit breakers on the primary and/or secondary, as required by the design. | Coordinate protective-device ratings with transformer capacity, conductor size, and applicable code. Check whether internal protection is provided or external protection is required. |
| Insulation and safety ratings | Applicable product safety standards, insulation class, dielectric withstand, and installation category where specified. | Ratings vary by construction, application, and market; they must be taken from the product documentation. | Choose equipment certified or evaluated for the intended jurisdiction and installation environment. Do not substitute a generic voltage rating for a verified safety rating. |
| Operating environment | Ambient temperature, humidity, altitude, vibration, enclosure, and indoor or outdoor installation. | Temperature range and enclosure protection are model-specific; outdoor use may require a suitable enclosure and environmental rating. | Check the full operating limits and any derating at elevated temperature or altitude. Consider condensation, dust, and corrosive conditions. |
| Network interface | Physical ports, media type, link speed, and connection distance. | Ethernet is commonly provided over copper twisted-pair cabling; some installations use fiber. Supported speed and distance depend on the port and cable category. | Match the interface to the site cabling and switches. Confirm connector type, cable requirements, and whether fiber or copper is required. |
| Communication protocols | Required application protocols and compatibility with meters, controllers, SCADA, or building-management systems. | Common examples include Modbus RTU over serial links, Modbus TCP over Ethernet, and other project-specified industrial protocols. | Verify protocol role and supported functions, not just the protocol name. Check register maps, data types, addressing, and any required gateway translation. |
| Serial communications | Whether RS-485, RS-232, or another serial interface is needed, including wiring and bus settings. | For RS-485, confirm two-wire or four-wire operation, baud rate, parity, termination, and biasing requirements. | Ensure the gateway supports the connected device’s serial settings and bus topology. Observe cable length and termination guidance for the installation. |
| Network addressing and services | Static or dynamic IP addressing, subnet and routing needs, DNS, time synchronization, and required ports. | These settings are defined by the site network; they are not universal gateway defaults. | Obtain an approved network configuration from the network administrator and document permitted traffic between network segments. |
| Redundancy and availability | Required uptime, redundant power or network paths, and behavior after a link or power failure. | Redundancy features are optional and depend on the gateway and system architecture. | Define recovery time and fail-safe behavior. Verify whether the application requires redundant supplies, switches, communications paths, or local data buffering. |
| Cybersecurity | Authentication, encryption, access control, firmware updates, logging, and secure configuration options. | Capabilities vary by device; network segmentation and least-privilege access are common security practices. | Review the site security policy, disable unused services, change default credentials, and confirm the update and vulnerability-support process. |
| Compliance and documentation | Required electrical, EMC, radio, and environmental approvals, plus wiring and communication documentation. | Applicable requirements depend on the country, installation type, and whether wireless functions are included. | Request current declarations, certificates, wiring diagrams, manuals, and protocol documentation for the exact configuration being installed. |