| Required Force | The linear push or pull force needed at the actuator rod or piston. | Approximately 10 N to 5,000 N for compact hydraulic applications. | Calculate the external load, friction, acceleration force, and any gravity component. Add a safety factor of about 1.25 to 1.50: Design Force = Calculated Load × Safety Factor. |
| Pressure | Hydraulic pressure available to generate actuator force. | Common compact-system values are approximately 70 to 250 bar, depending on construction and application. | Confirm that the actuator rating is equal to or higher than the maximum system pressure. Continuous operating pressure should not be treated as the same as short-duration peak pressure. |
| Piston Area | The effective hydraulic area on which pressure acts. | Typical bore diameters may range from about 6 mm to 25 mm in micro-cylinder designs. | Estimate theoretical extension force with F = P × A, where F is force in newtons, P is pressure in pascals, and A is piston area in square metres. Account for seal friction and mechanical losses. |
| Rod Diameter | The diameter of the actuator rod, which affects buckling strength, retraction force, and stiffness. | Often approximately 3 mm to 16 mm for compact actuators. | Select a rod large enough for compressive loading and side-load resistance. Retraction force is lower than extension force because the rod area reduces the effective return-side piston area. |
| Stroke Length | The maximum linear travel available from the fully retracted to the fully extended position. | Approximately 5 mm to 150 mm for many micro hydraulic applications. | Specify the actual required travel and include clearance at both end positions. Avoid using the mechanical end stop as the normal operating position. |
| Position Accuracy | How closely the actuator can reach and hold the commanded position. | Basic open-loop systems may provide millimetre-level positioning; feedback-controlled systems can achieve substantially finer repeatability under controlled conditions. | Define accuracy, repeatability, and resolution separately. If the load varies or the actuator must hold an intermediate position, consider a position sensor and a proportional or servo valve. |
| Operating Speed | The rate at which the piston or rod extends or retracts. | Approximately 1 to 300 mm/s, depending on flow rate, load, bore size, pressure, and valve configuration. | Use v = Q ÷ A, where v is speed, Q is flow rate, and A is effective piston area. Check both loaded and unloaded speeds, because actuator speed changes with load and available flow. |
| Flow Requirement | The hydraulic flow needed to achieve the specified speed. | Often approximately 0.05 to 5 L/min for compact hydraulic cylinders. | Estimate flow from Q = A × v, then add allowance for leakage, valve losses, temperature effects, and pump variation. Ensure the valve and tubing can deliver the required flow without excessive pressure drop. |
| Duty Cycle | The operating pattern, including run time, idle time, cycle frequency, and load profile. | Intermittent duty may be a few cycles per minute; continuous-duty designs require suitable cooling and component ratings. | State the number of cycles per hour, extension time, retraction time, dwell time, load during each movement, and standby pressure. Use the worst-case thermal condition for sizing. |
| Cycle Time | The total time required for one complete operating sequence. | Common compact-machine cycle times range from less than one second to several minutes. | Calculate extension time as Stroke ÷ Extension Speed and retraction time as Stroke ÷ Retraction Speed. Add dwell, valve response, and control-system delays. |
| Load Direction | Whether the actuator is pushing, pulling, lifting, lowering, or resisting an external force. | Push and pull loads should be specified separately because effective piston areas differ. | For lifting or lowering applications, include gravity, possible shock loading, and the risk of uncontrolled movement. A counterbalance, pilot-operated check valve, or mechanical lock may be required. |
| Side Load | A load acting perpendicular to the actuator axis. | Ideally near zero; external guides should carry most transverse loads. | Do not use the actuator rod as a structural guide. Use clevises, spherical joints, or external linear guides where alignment changes or side forces are present. |
| Mounting Arrangement | The method used to attach the actuator to the machine. | Common options include threaded bodies, front or rear pivots, clevis mounts, trunnions, and flange mounts. | Select a mounting style that permits correct alignment throughout the full stroke. Check mounting strength, available installation space, joint articulation, and access for maintenance. |
| Installation Envelope | The total space occupied by the actuator and its connections during operation. | Compact body diameters may be approximately 10 to 35 mm, with overall lengths determined by stroke and mounting design. | Check retracted length, extended length, port orientation, hose bend radius, connector clearance, and the space required for service or replacement. |
| Fluid Compatibility | The suitability of the hydraulic fluid for seals, cylinder materials, valves, and hoses. | Mineral hydraulic oils are common; water-based or biodegradable fluids require specifically compatible materials. | Specify fluid type, viscosity range, temperature range, cleanliness level, and seal material. Never assume that a seal compatible with mineral oil is suitable for water-based fluid. |
| Operating Temperature | The temperature range of the hydraulic fluid and surrounding environment. | A general design range may be approximately -20°C to 80°C, subject to seal, fluid, and material limitations. | Rate the actuator for the actual minimum and maximum temperatures. High temperature lowers fluid viscosity and can accelerate seal wear; low temperature increases viscosity and slows response. |
| Leakage Control | The ability of the actuator and circuit to limit internal and external hydraulic leakage. | Leakage performance depends on seal design, pressure, temperature, surface finish, contamination, and service life. | Define whether minor internal leakage is acceptable. For long-duration load holding, use an appropriate load-holding valve or mechanical locking method instead of relying only on the actuator seals. |
| Environmental Protection | Resistance to dust, moisture, chemicals, vibration, and corrosion. | Protection levels vary from indoor clean environments to sealed outdoor or washdown applications. | Identify exposure to water, dust, salt spray, chemicals, impact, and vibration. Specify suitable rod coatings, wipers, corrosion-resistant materials, and enclosure protection for the installation. |
| Safety Factor | The margin between the expected operating requirement and the actuator's rated capability. | A factor of approximately 1.25 to 1.50 is commonly used for predictable static loads; higher margins may be needed for shock or uncertain loads. | Apply the safety factor to force, pressure, speed, and structural loads as appropriate. Do not exceed the manufacturer's maximum pressure, buckling, or side-load limits. |