| 1. Define the load | Static and dynamic load | A support bracket must carry a 1.5 kN working load without permanent deformation. | Use a specified design factor and account for load direction, shock, and mounting conditions; do not size from working load alone. | Check material and fastener calculations, then inspect for permanent deformation after a controlled proof-load test. |
| 2. Specify speed and duty | Rotational speed and operating cycle | A bearing operates at up to 1,200 rpm under a 0.8 kN radial load. | Operating speed, load, lubrication, and duty cycle must remain within the selected bearing’s ratings and thermal limits. | Compare the operating point with the component ratings; monitor temperature and noise during a representative run. |
| 3. Set accuracy needs | Positioning accuracy and repeatability | A 300 mm linear axis must position within ±0.10 mm at the specified measurement points. | Account for backlash, alignment, thermal expansion, sensor resolution, and load-induced deflection. | Measure repeated moves across the full travel with a suitable calibrated displacement instrument. |
| 4. Establish stiffness limits | Deflection under load | A loaded support shaft must deflect no more than 0.20 mm at its specified working load. | Span, support arrangement, material, and applied load all affect deflection; strength alone is not sufficient. | Calculate deflection for the actual boundary conditions and confirm it with a loaded measurement if needed. |
| 5. Define the environment | Temperature, moisture, and contamination | The assembly must operate from −10 °C to 60 °C in an indoor area where occasional dust is present. | Check material compatibility, lubricant temperature range, sealing, and the effects of condensation or abrasive particles. | Review component environmental limits and test operation at the expected temperature extremes and exposure conditions. |
| 6. Fix the available envelope | Installed dimensions and clearance | The component must fit within a 120 mm × 80 mm × 60 mm installation space. | Reserve space for fasteners, tool access, wiring, adjustment, and moving-part clearance—not just the component body. | Check the assembly drawing and verify clearances through the full range of motion. |
| 7. Match materials to the setting | Corrosion, wear, and contact compatibility | Exposed hardware must tolerate occasional cleaning with a mild water-based detergent. | Consider cleaning chemicals, dissimilar-metal contact, wear surfaces, and the required corrosion resistance. | Confirm material and finish compatibility with the actual cleaning procedure and inspect representative parts after exposure. |
| 8. Specify interfaces | Mounting geometry and fit | A mounting plate uses four M8 fasteners on a 60 mm × 40 mm rectangular pattern. | Define hole tolerances, thread engagement, datum surfaces, alignment requirements, and access for installation. | Check dimensioned drawings and confirm the fit with a mating-part inspection or assembly trial. |
| 9. Plan maintenance | Service interval and accessibility | Routine inspection should be possible without removing the main drive assembly. | Lubrication intervals depend on component type, load, speed, contamination, and operating conditions; use the component’s instructions. | Review the maintenance procedure and verify that inspection and service points are accessible in the installed assembly. |
| 10. Define safe failure behavior | Failure mode and hazard control | A loss of drive power must not allow a vertical load to descend unexpectedly. | Do not rely on a drive component alone for personnel protection; assess the full system and applicable safety requirements. | Perform a documented risk assessment and test the specified power-loss and fault scenarios using an appropriate safe procedure. |