| Weight and handling | Typical glass-fiber-reinforced polymer (GFRP) density is about 1.8–2.0 g/cm³; carbon steel is about 7.85 g/cm³. | Compare the mass of the complete member, including fittings and connections, with the proposed steel or aluminum alternative. | Lower member weight can simplify lifting, transport, and installation, but confirm that the selected section meets strength and deflection requirements. |
| Strength and load capacity | Pultruded GFRP is anisotropic: its properties differ by direction. Strength along the reinforcing fibers is generally higher than strength across them. | Review design values for the actual profile, fiber orientation, wall thickness, load direction, support spacing, and connection details. | Use project-specific engineering calculations rather than a single generic “FRP strength” value. Check bending, shear, compression, local buckling, and combined loads as applicable. |
| Stiffness and deflection | GFRP generally has a lower elastic modulus than steel, so a lighter section may still deflect more under the same loading. | Check serviceability limits, span, support conditions, vibration, and long-term creep under sustained loads. | Select the section by both strength and allowable deflection; increasing section depth or wall thickness may improve stiffness. |
| Corrosion and chemical exposure | GFRP does not rust, but resin and reinforcement performance depend on the chemical, its concentration, temperature, and exposure duration. | Identify the specific chemicals, cleaning agents, immersion or splash conditions, operating temperature, and expected service life. | Confirm resin-system compatibility and any required surface veil or protective coating with technical data for the proposed profile. |
| Electrical and thermal properties | GFRP is generally electrically insulating and has lower thermal conductivity than metals. Conductive fillers or carbon reinforcement can change electrical behavior. | Determine whether electrical insulation, grounding, heat transfer, or thermal movement is a design requirement. | Do not assume every FRP profile is electrically non-conductive; verify the reinforcement and product specifications for the intended application. |
| Operating temperature | Temperature capability is governed largely by the resin system and the profile’s glass-transition temperature (Tg). | Check continuous and peak temperatures, temperature cycling, chemical exposure at temperature, and the specified design safety margin below Tg. | Obtain temperature-dependent mechanical data for the selected resin and profile rather than relying only on room-temperature values. |
| Fire, smoke, and heat release | FRP is combustible unless specifically formulated and tested for a required fire performance; “fire-retardant” does not mean non-combustible. | Review applicable building or process requirements, flame-spread criteria, smoke limits, and test standards for the installation location. | Specify a tested fire-performance grade when required and verify that the test evidence applies to the relevant profile and thickness. |
| UV and weather exposure | Prolonged sunlight can cause surface fading or degradation in some FRP products; protection depends on the resin, surface layer, and coating. | Assess outdoor exposure, climate, expected service life, and whether appearance or surface protection is important. | Ask for UV-weathering information and specify a suitable UV-resistant surface veil or coating where needed. |
| Connections and fabrication | FRP profiles can be cut and drilled using suitable tooling. Bolted connections require attention to bearing, edge distance, and local crushing. | Check connection loads, hole locations, washer or plate details, installation access, and compatibility of fasteners with the environment. | Design connections specifically for FRP; avoid transferring metal-profile details without checking local stresses and detailing requirements. |
| Dimensions and tolerances | Outside dimensions, wall thickness, corner radii, straightness, and cut length can vary by profile and manufacturing specification. | Confirm drawing tolerances, fit-up requirements, and whether the application depends on precise mating surfaces. | Request dimensional tolerances for the exact section and include them in procurement documents and assembly drawings. |
| Inspection and service life | FRP does not corrode like unprotected steel, but damage, delamination, UV effects, or chemical degradation may still require inspection. | Define inspection intervals and criteria for checking cracks, impact damage, exposed fibers, connection condition, and surface deterioration. | Base maintenance planning on the exposure conditions, design assumptions, and inspection guidance for the selected product. |