| Body material | Nonconductive thermoplastic or nylon | Lightweight polymer body; some lockout models also use a nonconductive polymer shackle. | Can help reduce electrical-conductivity concerns and resist many common chemicals. | Impact, temperature, UV, and chemical resistance vary by formulation. Confirm the product’s stated ratings; material alone does not establish electrical safety. | Electrical lockout applications when the padlock is specifically designed and rated for the intended environment. |
| Body material | Aluminum | Metal body with relatively low weight; commonly anodized or otherwise finished. | Light to carry and generally more rigid than a polymer body. | Conductive. Surface finishes can wear, and resistance to corrosion or chemicals depends on the alloy and finish. | General industrial lockout where electrical conductivity is not a concern and a lightweight metal body is preferred. |
| Body material | Brass | Metal body often used in conventional padlocks; brass is not electrically insulating. | Can offer useful corrosion resistance in some environments. | Conductive; performance varies with alloy and exposure. Check compatibility with site chemicals and conditions. | General-purpose use where the padlock’s construction and environmental ratings meet site requirements. |
| Shackle material | Hardened steel | Rigid metal shackle, commonly selected for resistance to cutting and forced attack. | Typically offers greater resistance to cutting than softer shackle materials of similar size. | Conductive and may corrode if its protection is damaged or the environment is corrosive. Does not make a padlock electrically safe. | Locations where physical tampering resistance is a priority and electrical hazards are not present at the lock point. |
| Shackle material | Stainless steel | Metal shackle available in different stainless grades and finishes. | Often chosen for improved corrosion resistance compared with unprotected carbon steel. | Conductive. Corrosion performance depends on grade, finish, and exposure; it should not be assumed to be corrosion-proof. | Wet or corrosive settings when the specified grade is appropriate for the exposure. |
| Shackle material | Aluminum | Lightweight metal shackle, generally softer than hardened steel. | Reduces carrying weight and may be less damaging to some surfaces than harder shackles. | Conductive and generally less resistant to cutting than hardened steel. Check strength and corrosion suitability for the task. | Applications where low weight is useful and the required level of physical security is modest. |
| Shackle type | Standard-height shackle | Conventional shackle clearance for many lockout points and hasps. | Compact and suitable for many common isolation devices. | Measure the attachment point; insufficient clearance can prevent proper installation. | Compact lockout points with adequate clearance. |
| Shackle type | Long or extended shackle | Provides additional vertical clearance compared with a standard-height shackle. | Can reach through larger hasps or around wider attachment points. | A longer shackle may provide more leverage for attack. Use only the clearance needed and verify that it fits securely. | Large hasps, valves, or isolation points that cannot accept a standard-height shackle. |
| Shackle type | Nonconductive shackle | Made from an insulating material, commonly specified for lockout applications involving electrical hazards. | Can reduce the risk of creating a conductive path through the shackle when properly designed and used. | May be less resistant to cutting or impact than a hardened metal shackle. Verify the product’s electrical and mechanical ratings and site procedures. | Electrical lockout points where a suitable, specifically rated nonconductive design is required. |
| Keying option | Keyed different | Each padlock in the group has a unique key; one key opens one assigned lock. | Supports individual ownership and reduces the chance that one worker’s key opens another worker’s lock. | Requires key control and a plan for lost keys. Confirm that spare keys are managed securely. | Personal lockout programs in which each authorized worker controls their own key. |
| Keying option | Keyed alike | A defined group of padlocks can be opened by the same key. | Convenient when one authorized person needs to operate several locks. | Shared-key access reduces individual key separation. Limit the group and control key distribution carefully. | Equipment sets assigned to one person or a controlled maintenance function. |
| Keying option | Master keyed | Individual locks have separate operating keys; an authorized master key can open a defined group. | Can support controlled supervisory or emergency access across multiple locks. | The master key creates broader access and must be tightly controlled. Follow site procedures and applicable lockout requirements. | Managed systems that require an authorized access hierarchy and documented key custody. |
| Key feature | Key-retaining when unlocked | The key cannot be removed while the padlock is unlocked. | Helps reduce the chance of a lock being left unlocked without its key. | Check the operating sequence and confirm it suits the site’s lockout procedure. | Lockout programs seeking a visible, practical reminder to relock before removing the key. |