| 1 | Packaged fire-tube | 5,000–100,000 lb/hr | 15–300 psig | Food processing, laundries, hospitals, and general process steam | Provide treated feedwater, reliable condensate return, regular waterside inspection, and burner tuning. Verify that the selected pressure and output meet the process load. |
| 2 | Large fire-tube | Up to about 100,000 lb/hr, depending on design | Typically 15–300 psig | Central plants and medium-to-large facilities with steady steam demand | Allow adequate room for installation and maintenance. Control water quality, blowdown, combustion air, and stack conditions; avoid sustained operation far below design load. |
| 3 | D-type water-tube | About 50,000–1,000,000+ lb/hr | Approximately 150–1,500 psig | Refineries, chemical plants, power and utility systems, and large process sites | Requires a site-specific pressure-part design, close feedwater chemistry control, trained operators, and code-compliant inspection. Higher-pressure service may require additional steam-purity controls. |
| 4 | O-type water-tube | About 10,000–500,000 lb/hr | Approximately 150–1,500 psig | Industrial plants needing a compact water-tube arrangement and responsive steam supply | Plan for suitable water treatment, safe access to pressure parts, regular burner and tube inspections, and operating procedures matched to the boiler’s pressure and load range. |
| 5 | A-type water-tube | About 10,000–500,000 lb/hr | Approximately 150–1,500 psig | Process plants where a water-tube design suits the available footprint and steam duty | Confirm clearances and maintenance access during layout. Maintain feedwater quality, burner safeguards, level controls, and inspection schedules in accordance with the approved design. |
| 6 | Modular packaged boiler plant | About 1,000–20,000 lb/hr per module | Commonly 15–300 psig | Facilities with variable demand, staged expansion, or a need for operating redundancy | Use coordinated sequencing controls and ensure each module operates within its specified turndown range. Provide adequate headers, isolation, feedwater capacity, and a maintenance plan for each unit. |
| 7 | Once-through / coil-type | About 500–50,000 lb/hr | Design-dependent; commonly 100–1,500 psig | Sites needing compact equipment, rapid steam response, or specialized process conditions | Follow the manufacturer’s specified feedwater chemistry and flow limits closely. Controls must protect against low flow, overheating, and unstable operation; operator and code requirements vary by jurisdiction and design. |
| 8 | Low-pressure process boiler | About 1,000–100,000 lb/hr | Typically up to 15 psig for low-pressure steam service | Building services, humidification, food preparation, and low-pressure process heating | Keep the system within its permitted pressure rating and use correctly set pressure controls and safety valves. Maintain water level, feedwater quality, condensate return, and routine safety checks. |
| 9 | High-pressure superheated-steam boiler | Typically 50,000–1,000,000+ lb/hr, project-dependent | Often 300–1,500+ psig, design-dependent | Power generation and industrial processes requiring superheated steam | Requires engineered superheater protection, precise temperature and pressure control, high-purity feedwater, qualified operating staff, and inspection under applicable pressure-vessel and boiler rules. |
| 10 | Lead-lag / standby boiler plant | Combined output depends on the number and size of boilers | Set by the individual boilers and system design | Continuous-process facilities where steam availability and maintenance flexibility are important | Size the plant for peak demand and the required backup duty. Test automatic changeover, isolation valves, alarms, and standby readiness; maintain each boiler even when it is not the lead unit. |