| Tip 1 | Accuracy | Check the maximum difference between the indicated angle and a traceable reference angle across the specified operating range. Confirm whether the quoted accuracy includes calibration error, temperature effects, and other error sources. | Look for a clearly stated limit, such as ±degrees or ±% of full scale, plus the test conditions. For an angular range of 360°, 0.1% of full scale corresponds to 0.36°. | Accuracy describes closeness to the true or reference angle. A stated value is difficult to compare unless its range, units, and conditions are defined. |
| Tip 2 | Resolution | For a digital sensor, check the number of output bits and whether the quoted resolution is nominal or usable. For an analog sensor, check the smallest reliably detectable change in the complete measurement system. | For an ideal 12-bit absolute output over 360°, the nominal step is 360° ÷ 4096, or about 0.088° per count. Actual measurement performance can be worse because of noise and other errors. | Resolution is the smallest output increment; it is not the same as accuracy. More bits do not by themselves guarantee a more accurate measurement. |
| Tip 3 | Linearity | Ask how the sensor’s output is compared with a reference line or ideal transfer function, and whether the result is specified over the full range or a smaller range. | Check the maximum deviation and its units, commonly degrees or percent of full scale. Confirm whether the specification is independent linearity or uses a best-fit reference line. | Linearity describes how consistently output follows the stated input-output relationship. Different reference-line methods can produce different reported values. |
| Tip 4 | Repeatability | Check repeated readings at the same angle under the same conditions. Review the number of repetitions, approach direction, warm-up state, and whether the result is a range or statistical measure. | Look for a stated repeatability limit in degrees, or for the measurement spread and method used to calculate it. Do not treat repeatability as a substitute for accuracy. | A sensor can return nearly identical readings each time yet still have a consistent offset from the true angle. |
| Tip 5 | Hysteresis and direction effects | Compare readings at the same angular positions while approaching from clockwise and counterclockwise directions. Check for mechanical backlash or direction-dependent output. | Request the maximum difference between readings at the same position for the two approach directions, stated in degrees and under defined test conditions. | Direction-dependent differences can affect positioning systems that reverse direction frequently. |
| Tip 6 | Operating conditions | Match the sensor’s specified temperature range, vibration and shock limits, ingress protection, supply voltage, and mounting requirements to the application. | Review the published environmental limits and the conditions used for performance specifications. Check the datasheet for temperature-related error or drift where relevant. | Performance measured under one set of conditions may not represent performance in the final installation. |
| Tip 7 | Output, interface, and calibration | Confirm that the output type, electrical interface, measurement range, zero position, direction convention, and update rate are compatible with the control system. | Check the output protocol or signal range, wiring requirements, calibration procedure, and any available test or calibration documentation. | A sensor with suitable measurement performance still needs to integrate correctly and maintain the required reference position in the application. |