| 1 | Carrier fill fraction | A design-dependent share of the reactor volume is occupied by moving carriers. A commonly encountered preliminary-design range is about 30–70%; the suitable value depends on carrier geometry, mixing, and screen design. | The proposed fill fraction, its design basis, and evidence that carriers remain properly mixed at the specified operating level. |
| 2 | Carrier protected surface area | Carrier products differ in shape and protected surface area. Nominal surface-area figures are not directly comparable unless the measurement method and usable area are clearly defined. | Carrier drawings, material data, stated surface-area definition, and the basis used to size the biological process. |
| 3 | Reactor configuration | MBBR systems can use aerobic, anoxic, or staged zones. Aerobic zones support processes such as carbon oxidation and nitrification; anoxic zones can support denitrification when suitable conditions and a carbon source are available. | A process-flow diagram showing each zone, carrier location, mixing or aeration method, and recycle streams where applicable. |
| 4 | Oxygen supply and mixing | Aerobic MBBR reactors require oxygen transfer and carrier movement. Dissolved-oxygen targets are process-specific; a preliminary aerobic design may use approximately 2–4 mg/L, subject to loading and operating conditions. | The aeration or mixing design, expected oxygen demand, control approach, and energy estimate at the stated design load. |
| 5 | Carrier-retention screens | Screens at reactor outlets retain carriers while allowing treated water to pass. Screen openings must suit the carrier dimensions, and the screen must be designed for hydraulic loading and fouling risk. | Screen opening size, open area, material, cleaning or maintenance provisions, and the design flow used for sizing. |
| 6 | Influent pretreatment | Screening and other suitable pretreatment help reduce the risk of clogging, excessive solids accumulation, and interference with carrier movement. Required pretreatment depends on influent solids and debris. | Influent assumptions and the recommended screening, grit removal, grease control, or equalization provisions. |
| 7 | Hydraulic retention time and loading | There is no single MBBR retention time that applies to all projects. Reactor sizing depends on flow, organic and ammonia loads, temperature, carrier characteristics, and required effluent quality. | Design flow and load calculations, operating assumptions, reactor volume, and expected performance at peak and average conditions. |
| 8 | Nitrification design basis | Nitrification is carried out by biofilm microorganisms and is affected by temperature, dissolved oxygen, alkalinity, ammonia loading, and inhibition. These factors must be considered in process sizing. | The ammonia design load, temperature and alkalinity assumptions, oxygen provision, and effluent target used in the calculation. |
| 9 | Solids separation and sludge handling | Biofilm naturally grows and sloughs from carriers. Downstream clarification or another solids-separation step is commonly needed to remove suspended solids from the treated water. | The complete treatment-train layout, expected solids load, separation equipment, and sludge-handling requirements. |
| 10 | Performance guarantees and validation | Treatment results depend on influent quality, temperature, operation, and the overall process train. A performance claim is meaningful only when the influent conditions, test method, and operating period are stated. | Comparable project references, pilot or commissioning data where available, defined guarantee conditions, and a clear list of exclusions. |