| Vane | Approximately 5–250 cm³/rev | Common designs reach roughly 100–210 bar | Fixed or variable displacement; single or double pumps; balanced or unbalanced designs | Relatively smooth flow and moderate noise; useful for steady-duty hydraulic systems | Check fluid cleanliness, operating temperature, pressure duty, and availability of the required displacement-control arrangement. |
| Axial piston | Approximately 5–1,000 cm³/rev, depending on design | Common industrial and mobile designs are rated around 250–420 bar | Swash-plate or bent-axis; fixed or variable displacement; pressure, load-sensing, or power control | High power density and suitability for high-pressure or variable-flow systems | Match control response, shaft and mounting interface, pressure rating, case-drain requirements, and fluid cleanliness. |
| Radial piston | Design-dependent; commonly selected for low-to-moderate flow applications | Some designs operate at several hundred bar; confirm the model rating | Fixed or variable displacement; multiple piston arrangements | Can provide high pressure at comparatively low flow | Verify duty cycle, pulsation, speed limits, pressure rating, and service requirements for the specific design. |
| External gear | Approximately 0.5–250 cm³/rev, depending on construction | Many standard designs are rated around 160–250 bar; heavier-duty designs may be higher | Fixed displacement; single or multiple sections; different shaft and port configurations | Compact construction, simple operation, and broad availability | Check continuous versus intermittent pressure ratings, noise, inlet conditions, and compatibility with the working fluid. |
| Internal gear | Approximately 1–250 cm³/rev, depending on design | Common industrial designs are often rated around 160–250 bar | Fixed displacement; optional pressure-balancing features | Smooth delivery and typically low noise in suitable operating conditions | Compare viscosity range, speed limits, inlet pressure, and the pump’s pressure rating at the intended speed. |