| UV lamp type | The practice uses fluorescent UV lamps. UVA-340 lamps are commonly selected to simulate the short-wavelength UV portion of sunlight; the lamp type should be stated in the test report. | Lamp type, specimen orientation, and the test setup used. | Helps buyers compare test reports made under comparable exposure conditions. |
| UV exposure and moisture cycle | A commonly used Cycle 1 sequence is 8 hours of UV exposure followed by 4 hours of condensation. The cycle and its settings must be specified; other procedures may be used. | Cycle number, UV and moisture durations, and any departures from the selected procedure. | UV plus moisture exposure offers a controlled way to examine weathering-related changes. |
| Exposure temperature | For the commonly used Cycle 1 sequence, the UV step is typically controlled at a 60 °C black-panel temperature and the condensation step at 50 °C. Check the applicable standard edition and laboratory procedure. | Temperature setpoints, control method, and total exposure time. | Makes laboratory conditions transparent; accelerated exposure is not a direct conversion to outdoor service years. |
| Irradiance setting | Irradiance is controlled at a selected wavelength when the apparatus and procedure call for it. A commonly specified UVA-340 setting is 0.89 W/(m²·nm) at 340 nm; the chosen setting should be reported. | Wavelength, irradiance setpoint, and calibration or control details. | Allows meaningful comparison only when the exposure settings are also comparable. |
| Physical appearance | ASTM G154 specifies exposure conditions, not a universal visual rating or acceptance threshold. Inspect specimens before and after exposure using documented criteria. | Color change, surface chalking, cracking, embrittlement, or other visible changes; include photographs and a stated rating method where used. | Appearance matters where the cover remains visible or weathering could affect handling. |
| Mechanical-property retention | Measure relevant properties before and after exposure using a separately selected, appropriate test method. ASTM G154 itself does not prescribe a universal tensile-retention requirement. | Breaking strength, elongation, or another specified property, with specimen direction, conditioning, method, and results recorded. | Helps assess whether the tarp can retain the performance needed for its intended use. |
| Test duration and acceptance criteria | Choose exposure duration and pass/fail limits for the material and application before testing. ASTM G154 does not define a single required duration or universal pass/fail value for plastic tarpaulins. | Total exposure hours or cycles, agreed acceptance limits, and all pre- and post-exposure measurements. | A clear specification supports supplier evaluation without treating laboratory hours as guaranteed field lifespan. |